10
iNET Series Installation & Start-Up MDS 05-2873A01, Rev. E
c. Press the ENTER key. A login screen will be displayed that
requires a password (default = admin) to access the Menu Sys-
tem. A password is required to make changes to all parame-
ters.
d. Program the radio’s Network Name.
e. Review other settings and make changes if necessary, such as
the unit password, IP address and security.
Repeat the above steps for each unit in the network.
NOTE: The Menu System’s “configuration files” will aid in
uniformly configuring multiple units. The use of these files is
described in the User’s Guide.
Step 5—Connect the Data Equipment
Ethernet Example: Connect Ethernet-compatible data equipment to
the unit’s
LAN port (10BaseT), or one of the serial ports, depending on
the capability of your transceiver. (See Table 1 on Page 4.)
Use a straight-through Ethernet cable to connect the
LAN port to a hub,
and a crossover cable to connect it directly to an Ethernet station. See
the Reference Chart at the middle of this guide for more information.
IP-to-Serial Example: From the PC, establish a TCP connection to
the IP address of the Remote transceiver and to the IP port. A Telnet
client application can be used to establish this connection. Data may
now be sent between the PC and the RTU or other connected device.
Configure the port as shown in Table 4.
Table 4. Serial Port Configuration (IP-to-Serial Connection)
Transceiver
Location
Menu Item Setting
Access Point None is required None is required
Remote Unit IP Address 192.168.0.2
Status Enabled
IP Protocol TCP
Baud Rate 9,600 (Example)
Flow Control None
Local IP Port 30011