MDS MX-2104 Especificaciones Pagina 122

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 243
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 121
Chapter 4 Operation MX-2100/2104 Installation and Operation Manual
4-18 Operating Instructions
• Check the settings of switch SW3 on the KCL module:
Section 1 - Master/Slave: OFF
Section 2 – DB INIT: OFF
Section 3 – PSWRD: OFF
Section 4 – DEBUG: OFF
• Check that all the communication equipment serving the main links operates
properly.
• Check all the configuration parameters against the prescribed set of
parameters.
• Press the RESET push-button of the KCL module.
If these actions do not correct the problem, refer to Chapter 5, Diagnostics to
identify the fault and replace the corresponding module.
Turn Off
➤ To stop equipment operation, use the following procedure:
1. If the MX-2100 includes a KM-Ringer module, first turn the KM-Ringer off
before the MX-2100.
2. Turn the MX-2100 off by setting the ON/OFF switches of the KPS modules
installed in the enclosure to OFF.