MX-2100/2104 Installation and Operation Manual Appendix F Command Set Description
Commands F-37
DSP HDR TST
Purpose
Display the results of the last hardware test of the KCL and KPS modules (made
during power-up self-test and during regular operation).
Format
DSP HDR TST
Use
• To display the hardware test report, type:
DSP HDR TST <ENTER>
Display Format
The display shows NO ERROR if everything checks good, or lists the detected
problem:
DATABASE 1 CHKSUM ERROR
DATABASE 2 CHKSUM ERROR
I/O EXPANDER ERROR
COUNTER ERROR
PS-A 5 VOLT FAILURE
PS-A 12 VOLT FAILURE
PS-B 5 VOLT FAILURE
PS-B 12 VOLT FAILURE
Refer to the Alarms appendix for an interpretation of the error messages.
DSP MANAGER LIST
Purpose
Display the network management stations to which the SNMP agent of MX-2100
sends traps. Each network management station is displayed by its IP address and
the corresponding subnet mask.
Format
DSP MANAGER LIST
Use
• To display all the IP and SUBNET MASK addresses, type:
DSP MANAGER LIST <ENTER>